{"created":"2023-06-19T11:28:11.906021+00:00","id":114,"links":{},"metadata":{"_buckets":{"deposit":"b517e676-fae2-4a54-9512-7226e7ca7b37"},"_deposit":{"created_by":18,"id":"114","owners":[18],"pid":{"revision_id":0,"type":"depid","value":"114"},"status":"published"},"_oai":{"id":"oai:kochireha.repo.nii.ac.jp:00000114","sets":["6:25"]},"author_link":["897","900","899","898","895","906","894","901","896","902","907","893","903","908","905","904"],"item_10002_biblio_info_7":{"attribute_name":"書誌情報","attribute_value_mlt":[{"bibliographicIssueDates":{"bibliographicIssueDate":"2009-03-31","bibliographicIssueDateType":"Issued"},"bibliographicPageEnd":"13","bibliographicPageStart":"9","bibliographicVolumeNumber":"10","bibliographic_titles":[{"bibliographic_title":"高知リハビリテーション学院紀要"},{"bibliographic_title":"Journal of Kochi Rehabilitation Institute","bibliographic_titleLang":"en"}]}]},"item_10002_description_5":{"attribute_name":"抄録","attribute_value_mlt":[{"subitem_description":"重度脳性麻痺児症例に対して,コンピュータのスイッチ操作を行う時の体圧分布状況を測定した.体圧分布の測定部位は,頭頸部と肩・背部で,測定項目は,最大圧力,平均圧力,センサー数の3指標であった.結果,症例1,2とも頭頸部の指標は安静時と比較し訓練時において有意に減少した.肩・背部では,3指標に一貫した傾向はみられなかった.症例1,2とも頭頸部の3指標が訓練時に有意に減少したことは,コンピュータのスイッチ操作時に筋緊張の亢進など過剰な努力のない状態でスイッチを使用できたことが考えられた.体圧分布の評価方法は,手順が整えば技術的にそれほど困難でないため,妥当なスイッチフィッティングを実施するために活用可能なものと思われた.","subitem_description_type":"Abstract"}]},"item_10002_description_6":{"attribute_name":"内容記述","attribute_value_mlt":[{"subitem_description":"We measured the distribution of body pressure in two children with severe cerebral palsy while they operated computer switches.We measured the maximum and minimum pressures as well as the required number of sensors in the head/neck and shoulder/back areas. In both children,the maximuminimum pressures and required number of sensors on the head/neck areas were significantly lower or fewer during switch operation,compared to during rest.On the other hand,there were no marked differences in measurements of the shoulder/back area.This indicates that the children operated computer switches in a relaxed manner without overstraining the muscles. The measurement of the distribution of body pressure does not require complex procedures or techniques,and is effective in determining appropriate switch-fitting.","subitem_description_type":"Other"}]},"item_10002_full_name_3":{"attribute_name":"著者別名","attribute_value_mlt":[{"nameIdentifiers":[{"nameIdentifier":"901","nameIdentifierScheme":"WEKO"}],"names":[{"name":"Inada, Tsutomu"}]},{"nameIdentifiers":[{"nameIdentifier":"902","nameIdentifierScheme":"WEKO"}],"names":[{"name":"Kouchi, Masato"}]},{"nameIdentifiers":[{"nameIdentifier":"903","nameIdentifierScheme":"WEKO"}],"names":[{"name":"Shinoda, Kaori"}]},{"nameIdentifiers":[{"nameIdentifier":"904","nameIdentifierScheme":"WEKO"}],"names":[{"name":"Shigeshima, Koji"}]},{"nameIdentifiers":[{"nameIdentifier":"905","nameIdentifierScheme":"WEKO"}],"names":[{"name":"Nono, Atsushi"}]},{"nameIdentifiers":[{"nameIdentifier":"906","nameIdentifierScheme":"WEKO"}],"names":[{"name":"Yoshimura, Chisako"}]},{"nameIdentifiers":[{"nameIdentifier":"907","nameIdentifierScheme":"WEKO"}],"names":[{"name":"Honda, Risa"}]},{"nameIdentifiers":[{"nameIdentifier":"908","nameIdentifierScheme":"WEKO"}],"names":[{"name":"Kumon, Masamitsu"}]}]},"item_10002_publisher_8":{"attribute_name":"出版者","attribute_value_mlt":[{"subitem_publisher":"高知リハビリテーション学院"}]},"item_10002_source_id_9":{"attribute_name":"ISSN","attribute_value_mlt":[{"subitem_source_identifier":"13455648","subitem_source_identifier_type":"ISSN"}]},"item_creator":{"attribute_name":"著者","attribute_type":"creator","attribute_value_mlt":[{"creatorNames":[{"creatorName":"稲田, 勤"}],"nameIdentifiers":[{"nameIdentifier":"893","nameIdentifierScheme":"WEKO"}]},{"creatorNames":[{"creatorName":"高地, 正音"}],"nameIdentifiers":[{"nameIdentifier":"894","nameIdentifierScheme":"WEKO"}]},{"creatorNames":[{"creatorName":"篠田, かおり"}],"nameIdentifiers":[{"nameIdentifier":"895","nameIdentifierScheme":"WEKO"}]},{"creatorNames":[{"creatorName":"重島, 晃史"}],"nameIdentifiers":[{"nameIdentifier":"896","nameIdentifierScheme":"WEKO"}]},{"creatorNames":[{"creatorName":"野々, 篤志"}],"nameIdentifiers":[{"nameIdentifier":"897","nameIdentifierScheme":"WEKO"}]},{"creatorNames":[{"creatorName":"吉村, 知佐子"}],"nameIdentifiers":[{"nameIdentifier":"898","nameIdentifierScheme":"WEKO"}]},{"creatorNames":[{"creatorName":"本田, 梨佐"}],"nameIdentifiers":[{"nameIdentifier":"899","nameIdentifierScheme":"WEKO"}]},{"creatorNames":[{"creatorName":"公文, 正光"}],"nameIdentifiers":[{"nameIdentifier":"900","nameIdentifierScheme":"WEKO"}]}]},"item_files":{"attribute_name":"ファイル情報","attribute_type":"file","attribute_value_mlt":[{"accessrole":"open_date","date":[{"dateType":"Available","dateValue":"2012-10-31"}],"displaytype":"detail","filename":"09-13.PDF","filesize":[{"value":"233.6 kB"}],"format":"application/pdf","licensetype":"license_note","mimetype":"application/pdf","url":{"label":"09-13","url":"https://kochireha.repo.nii.ac.jp/record/114/files/09-13.PDF"},"version_id":"1bd41aee-deeb-4c92-8902-5b76fb7d2dbe"}]},"item_keyword":{"attribute_name":"キーワード","attribute_value_mlt":[{"subitem_subject":"コンピュータ,脳性麻痺,スイッチフィッティング,体圧分布測定","subitem_subject_scheme":"Other"},{"subitem_subject":"Computer,Cerebral_palsy,Switch-fitting,Measurement_of_the_distribution_of_body_pressure","subitem_subject_language":"en","subitem_subject_scheme":"Other"}]},"item_language":{"attribute_name":"言語","attribute_value_mlt":[{"subitem_language":"jpn"}]},"item_resource_type":{"attribute_name":"資源タイプ","attribute_value_mlt":[{"resourcetype":"departmental bulletin paper","resourceuri":"http://purl.org/coar/resource_type/c_6501"}]},"item_title":"重度脳性麻痺児におけるスイッチ操作時の体圧分布","item_titles":{"attribute_name":"タイトル","attribute_value_mlt":[{"subitem_title":"重度脳性麻痺児におけるスイッチ操作時の体圧分布"},{"subitem_title":"The distribution of body pressure in children with severe cerebral palsy while operating computer switches","subitem_title_language":"en"}]},"item_type_id":"10002","owner":"18","path":["25"],"pubdate":{"attribute_name":"公開日","attribute_value":"2012-10-31"},"publish_date":"2012-10-31","publish_status":"0","recid":"114","relation_version_is_last":true,"title":["重度脳性麻痺児におけるスイッチ操作時の体圧分布"],"weko_creator_id":"18","weko_shared_id":-1},"updated":"2023-06-19T11:36:23.901162+00:00"}