{"created":"2023-06-19T11:28:11.217488+00:00","id":103,"links":{},"metadata":{"_buckets":{"deposit":"b3caf615-c0ff-417d-8683-5285e55200e0"},"_deposit":{"created_by":18,"id":"103","owners":[18],"pid":{"revision_id":0,"type":"depid","value":"103"},"status":"published"},"_oai":{"id":"oai:kochireha.repo.nii.ac.jp:00000103","sets":["6:23"]},"author_link":["817","822","818","821","819","820"],"item_10002_biblio_info_7":{"attribute_name":"書誌情報","attribute_value_mlt":[{"bibliographicIssueDates":{"bibliographicIssueDate":"2008-03-31","bibliographicIssueDateType":"Issued"},"bibliographicPageEnd":"21","bibliographicPageStart":"17","bibliographicVolumeNumber":"9","bibliographic_titles":[{"bibliographic_title":"高知リハビリテーション学院紀要"},{"bibliographic_title":"Journal of Kochi Rehabilitation Institute","bibliographic_titleLang":"en"}]}]},"item_10002_description_5":{"attribute_name":"抄録","attribute_value_mlt":[{"subitem_description":"本研究の目的は,人工呼吸器装着下における肺コンプライアンス測定の再現性を明らかにすることである.対象は人工呼吸器を装着した呼吸不全患者19例であり,肺コンプライアンスの測定は,人工呼吸器を用いて動的肺コンプライアンス(Cdyn)と静的肺コンプライアンス(Csta)について実施した.各測定は,1症例につき2名の検者が行い,測定の検者内および検者間の再現性について検討した.その結果,Cdyn,Csta における検者内および検者間の級内相関係数は,いずれも0.9を上回る良好な値を示していた.人工呼吸器装着下における肺コンプライアンスの測定は,検者内,検者間とも極めて良好な再現性があり,臨床場面において活用可能なものと考えられた","subitem_description_type":"Abstract"}]},"item_10002_description_6":{"attribute_name":"内容記述","attribute_value_mlt":[{"subitem_description":"The purpose of this study was to clarify the reliability of pulmonary compliance determination under artificial respiration conditions.The subjects of study were 19 respiratory failure patients undergoing artificial respiration.Dynamic (Cdyn) and static (Csta) pulmonary compliance were determined with an artificial respirator.Two staff members performed the measurements on each patient,and intra-and inter-staff reliability was investigated.As a result,intra-class correlation coefficient for both intra-and inter-staff reliability exceeded 0.9,indicating favorable reliability.Accordingly,we believe that because intra-and inter-staff reliability was satisfactory,pulmonary compliance determination in patients undergoing artificial respiration is a clinically viable method.","subitem_description_type":"Other"}]},"item_10002_full_name_3":{"attribute_name":"著者別名","attribute_value_mlt":[{"nameIdentifiers":[{"nameIdentifier":"820","nameIdentifierScheme":"WEKO"}],"names":[{"name":"Yokoyama, Hitoshi"}]},{"nameIdentifiers":[{"nameIdentifier":"821","nameIdentifierScheme":"WEKO"}],"names":[{"name":"Morio, Yuji"}]},{"nameIdentifiers":[{"nameIdentifier":"822","nameIdentifierScheme":"WEKO"}],"names":[{"name":"Hiraki, Koji"}]}]},"item_10002_publisher_8":{"attribute_name":"出版者","attribute_value_mlt":[{"subitem_publisher":"高知リハビリテーション学院"}]},"item_10002_source_id_9":{"attribute_name":"ISSN","attribute_value_mlt":[{"subitem_source_identifier":"13455648","subitem_source_identifier_type":"ISSN"}]},"item_creator":{"attribute_name":"著者","attribute_type":"creator","attribute_value_mlt":[{"creatorNames":[{"creatorName":"横山, 仁志"}],"nameIdentifiers":[{"nameIdentifier":"817","nameIdentifierScheme":"WEKO"}]},{"creatorNames":[{"creatorName":"森尾, 裕志"}],"nameIdentifiers":[{"nameIdentifier":"818","nameIdentifierScheme":"WEKO"}]},{"creatorNames":[{"creatorName":"平木, 幸治"}],"nameIdentifiers":[{"nameIdentifier":"819","nameIdentifierScheme":"WEKO"}]}]},"item_files":{"attribute_name":"ファイル情報","attribute_type":"file","attribute_value_mlt":[{"accessrole":"open_date","date":[{"dateType":"Available","dateValue":"2012-10-31"}],"displaytype":"detail","filename":"P17-21(22).PDF","filesize":[{"value":"254.1 kB"}],"format":"application/pdf","licensetype":"license_note","mimetype":"application/pdf","url":{"label":"P17-21(22)","url":"https://kochireha.repo.nii.ac.jp/record/103/files/P17-21(22).PDF"},"version_id":"1ed66237-db93-48e0-9a58-56e8d627ce3f"}]},"item_keyword":{"attribute_name":"キーワード","attribute_value_mlt":[{"subitem_subject":"肺コンプライアンス,人工呼吸器,再現性","subitem_subject_scheme":"Other"},{"subitem_subject":"pulmonary_compliance,respirator,reliability","subitem_subject_language":"en","subitem_subject_scheme":"Other"}]},"item_language":{"attribute_name":"言語","attribute_value_mlt":[{"subitem_language":"jpn"}]},"item_resource_type":{"attribute_name":"資源タイプ","attribute_value_mlt":[{"resourcetype":"departmental bulletin paper","resourceuri":"http://purl.org/coar/resource_type/c_6501"}]},"item_title":"人工呼吸器装着下における肺コンプライアンス測定の再現性","item_titles":{"attribute_name":"タイトル","attribute_value_mlt":[{"subitem_title":"人工呼吸器装着下における肺コンプライアンス測定の再現性"},{"subitem_title":"Reliability of pulmonary compliance determination under artificial respiration conditions","subitem_title_language":"en"}]},"item_type_id":"10002","owner":"18","path":["23"],"pubdate":{"attribute_name":"公開日","attribute_value":"2012-10-31"},"publish_date":"2012-10-31","publish_status":"0","recid":"103","relation_version_is_last":true,"title":["人工呼吸器装着下における肺コンプライアンス測定の再現性"],"weko_creator_id":"18","weko_shared_id":-1},"updated":"2023-06-19T11:36:47.485206+00:00"}